1 T Clamping Force Package Testing Equipment For Clamp Compression Testing
Clamp Compression Testing Method of Large Products
1.Before placing the packaged product between platens, verify that the clamp force using the clamp indicator. The indicator should be placed between the axes of the platen articulation points approximately 1/2 way up the platens.
2.Each time the product is clamped, the force should be applied for a minimum of 15 seconds and not to exceed 1 minute.
3. This Equipment applies the clamp force on the sample with the platens resting on the floor and the front edge of the platens flush with the front of the package. If the package is too large for the clamps to be flush to front edge (i.e., large refrigerator, tractor etc.), clamp as close to the edge as possible.
4. Clamp the product a total of 10 times in the flush orientation.
5. Apply the clamp force on the packaged product with the platens in a 6×6 inch(15.2x15.2cm) offset position. Both the horizontal and vertical offset dimensions are measured at the front bottom corner of the platen. If the package is too large for the clamp to be positioned 6-inches from the front edge (i.e., large refrigerator, tractor etc.), clamp as close to this position as possible.
6. Clamp the product a total of 10 times with the clamp in the 6 x6 inch offset position.
7. Repeat step 5 except with a 2 x6 inch offset clamp position. The 2 x6 inch offset is similar to the 6 x6 inch offset except the platens are oriented such that they are 2-inches from the floor and 6-inches back from the package’s front edge. If the package is too large for the clamps to be positioned 2-inches from the front edge (i.e., large refrigerator, tractor etc.), clamp as close to this position as possible.
8. Repeat flush and offset clamping on all other sides of the product that are indicated in the handling graphics as acceptable for clamp handling.
According to verdict standards, if there is one item failed the test, then put forward the “Test Failure Handling Sheet"
Techinical Parameters For Large Product
Clamping force |
1T |
color |
optional |
Resolution |
1/100,000 |
Test Space(L x W x H) |
100x 100 x 100cm |
Test Speed |
10±3mm/min |
Weight |
around 300kg |
Power |
1#, 220V/50HZ |
Safety protection
Overload protection, overvoltage protection & limited position protection device
Clamp Compression Testing Method of Small Products
Before clamp testing, verify that the clamp for using the clamp force indicator. The indicator should be placed between the axes of the platen articulation points approximately 1/2 way up the platens.
During clamp compression testing of small products, 4 samples will be utilized as outlined below.
1. When oriented for clamp testing (based on the handling graphics) the sides perpendicular to the platens of a single sample ≤ 24” (61cm), then the 4 sample should be placed in a”side by side”oritentation (with 2 samples on the bottom and 2 on the top)
2. If, when oriented for clamp testing the sides perpendicular to the platens of a single sample are >24” (61cm),, then the 4 samples should be placed in a top-bottom orientation. If, when placed 4-high, any of the samples are completely above the top of the platens, that sample can be removed from clamping in this orientation only
3 Each time the samples are clamped, the force should be applied for a minimum of 15 seconds and not to exceed 1 minute.
4 .Apply the clamp force on the samples with the platens resting on the floor and the samples flush with the front edge of the platens. If the samples are too large for the clamps to be flush to front edge, clamp as close to the edge as possible.
5.Clamp the product a total of 10times with the clamps in the flush orientation.
6.ASTM D6055 PLC Control Package Compression Testing MachineApply the clamp force on the packaged product with the platens in a 2×2 inch offset position. Both the horizontal and vertical offset dimensions are measured at the front bottom corner of the platen. If the package is too large for the clamps to be positioned 2-inches from the front edge, clamp as close to this position as possible.
7. Clamp the product a total of 10 times with the clamps in the offset position.
8. Repeat the flush and 2x2 inch offset camping on all other sides of the product that are identified in the handling graphics as acceptable for clamp handling. Please note, depending on the box geometry, you may use both the side-by-side and top-bottom orientation during clamp testing.
Techinical Parameters for Small Product
Clamping force: |
50-3000kg |
Size of the clamping board: |
1200 by 1200mm |
Maximum clamping space: |
1200 by 1200 by 1200mm |
Related Search
Testing Equipment
Compression Testing Machine
Testing Machine
Tensile Testing
Universal Testing
Laboratory Testing
More>>
Find more related products in following catalogs on Hisupplier.comCompany InfoDongguan Liyi Environmental Technology Co., Ltd. [China (Mainland)]
Business Type:Manufacturer You May Like:
Printable Page
Bookmark this page
Sitemap XML About HiSupplier Help Center Customer Service Friend Links Site Map Archives Browse by: China Suppliers - Hot Products - Products Directory - Offers Directory - Suppliers Directory - Buyers Directory Language Option: العربية - Nederlands- Français- Deutsch- Italiano- 日本語- 한국의- Português- Pусский- Español Copyright © HiSupplier.com Online Inc. All Rights Reserved.
|